WARNING!

NEVER

use a ground fault circuit interrupt (GFCI) wall outlet with this treadmill. As with any

appliance with a large motor, the GFCI will trip often. Route the power cord away from any
moving part of the treadmill including the elevation mechanism and transport wheels.

NEVER

remove any cover without first disconnecting AC power.

If voltage varies by ten percent (10%) or more, the performance of your treadmill may be
affected.

Such conditions are not covered under your warranty.

If you suspect the voltage

is low, contact your local power company or a licensed electrician for proper testing. See
Diagnosis Guide, page 16.

NEVER

expose this treadmill to rain or moisture. This product is

NOT

designed for use outdoors,

near a pool or spa, or in any other high humidity environment. The environmental specification
for temperature is 40 to 120 degrees Fahrenheit, and humidity limit is 95%, non-condensing (no
water drops forming on surfaces).

This product must be grounded. If the treadmill should malfunction or breakdown, grounding
provides a path of least resistance for electric current, reducing the risk of electric shock. This
product is equipped with a cord having an equipment-grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local
codes and ordinances.

DANGER - Improper connection of the equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt
as to whether the product is properly grounded. Do not modify the plug provided with the
product if it will not fit the outlet; have a proper outlet installed by a qualified electrician.

This product is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the
plug illustrated below. A temporary adapter that looks like the adapter illustrated below may be
used to connect this plug to a 2-pole receptacle as shown below if a properly grounded outlet is
not available. The temporary adapter should be used only until a properly grounded outlet,
(shown below) can be installed by a qualified electrician. The green colored rigid ear-lug, or the
like, extending from the adapter, must be connected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal
screw.

Important Electrical Information

Grounding Instructions

Grounded Outlet

Grounding Pin

Grounded Outlet Box

Metal Screw

Adapter

Tab of

Grounding

Screw