7. MAINTENANCE, TROUBLESHOOTING

7-6

7.7.4 Sounder

Requires Network Sounder ETR-6/10N/30N.

Sounder troubleshooting

If… But… Then…

you selected a sounder
display with the DISP key

picture does not appear

•

check that the network
sounder’s signal cable is firmly
fastened.

•

Check that sounder source is
correct.

•

check that the network sounder
is p

lugged in

. The LED on the

network sounder should flash
every second.

marks and characters
appear

picture does not appear

•

check for loosened transducer
connector.

the picture appears

zero line does not appear

•

the picture is shifted. Confirm
shift setting.

picture sensitivity is too low

—

•

check gain setting, if using
manual operation.

•

marine life or air bubbles may

be clinging to transducer face.

•

bottom may be too soft to return
a suitable echo.

the depth indication is not
displayed

—

•

adjust gain and range to display
the bottom echo (in reddish
brown), if you are using the
manual sounder mode.

noise or interference shows
on the display

—

•

check to be sure the transducer
cable is not near ship’s engine.

•

check the ground.

•

other video sounders of the
same frequency as yours may
be operating near you.

the water temperature graph
appears

data is wrong

•

check that sensor cable is tightly
fastened.