Installation instructions, Window requirements, Installation – Friedrich ZStar User Manual

Page 10

Advertising
background image

8

Installation Instructions

OUTDOORS

INDOORS

INNER

SILL

OUTER

SILL

INNER

SILL

WOOD STRIP MOUNTED

ON TOP OF INNER SILL

WOOD STRIP

FOR L BRACKET

3

/

4

"

CLEARANCE

1" MAX.

STORM

WINDOW

FRAME

OUTDOORS

INDOORS

OUTER

SILL

TYPE B: 5EA

(WOOD SCREW)

HARDWARE

TYPE A: 11EA

(SHORT SCREW)

TYPE C: 3EA

(L BRACKET)

TYPE E: 1EA

(SASH SEAL)

(Not adhesive backed)

TYPE D: 1EA

(SEAL STRIP)

(Adhesive backed)

TYPE F: 2EA

(GUIDE PANEL)

TYPE G: 1EA

(SUPPORT BRACKET)

10mm

16mm

Fig. 5-1

Fig. 5-2

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

1. This unit is designed for installation in standard double hung windows with actual opening widths of

22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 13"
from the bottom of the sash to the window stool.

2.If storm window presents interference, fasten a 2" wide wood strip to the inner window sill across

the full width of the sill. The wood strip should be thick enough to raise the height of the window sill
so that the unit can be installed without interference by the storm window frame.
See Fig. 5-2. The top of the wood strip should be approximately

3

/

4

" higher than the storm window

frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain
properly to the outside.

3. Install a second wood strip (approximately 6" long by 1

1

/

2

" wide and same thickness as first strip) in

the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as
shown Fig. 5-2.

4. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF

INNER SILL is more than 1", two of wood strips are not necessary.