Installation instructions, Electrical data – Friedrich ZStar User Manual

Page 12

Advertising
background image

10

Installation Instructions

Do not under any
circumstances cut
or remove the
grounding prong
from the plug.

Line Cord Plug

Use Wall Receptacle

Power Supply

Power supply cord with
3-prong grounding plug

Standard 125V, 3-wire grounding
receptacle rated 15A, 125V AC

Use 15 AMP, time
delay fuse or circuit
breaker.

TYPE B

SASH SEAL

(TYPE E)

L BRACKET

TYPE A

TYPE B

Support Bracket (TYPE G)

Fig. 12

Fig. 13

4. SECURE THE GUIDE PANELS

Extend the Guide Panels (TYPE F) to fill the window
opening using 4 screws (TYPE B) to secure them, as
shown in Fig. 12.

5. INSTALL THE SASH SEAL AND SASH LOCK

a. Cut the Sash Seal (TYPE E) to the window width.

Stuff the Sash Seal between the glass and the
window to prevent air and insects from getting into
the room, as shown in Fig. 12.

b. Fasten the L bracket using a screw (TYPE A), as

shown in Fig. 12.

6. a. Remove the screws that secure the cabinet and

base pan in the right side.

b. Fasten the support bracket (TYPE G) using a

removed screw. Attach the suport bracket (TYPE G)
in the inner window sill with a screw (TYPE B), as
shown Fig. 13.

7. Window installation of room air conditioner is now

completed. See ELECTRICAL DATA for attaching
power cord to electrical outlet.

REMOVAL FROM WINDOW

Turn the air conditioner off, disconnect the power cord, remove the L bracket, the screws and Support Bracket
installed through the top and bottom of the Guide Panels, and save for reinstallation later. Close the Guide Panels.
Keeping a firm grip on the air conditioner, raise the sash, and carefully tilt the air conditioner backward, draining
any condensate. Lift the air conditioner from the window and remove the sash seal from between the windows.

Electrical Data