Technical data, Symbols, Functional description – Festool OF 1400 EQ User Manual

Page 6: Use for intended purpose, Electrical connection, Extension cable, Switching the ma- chine on and off

Advertising
background image

6

TO REDUCE THE RISK OF

INJURY, USER MUST READ AND UNDER-

STAND INSTRUCTION MANUAL.

Technical data

Power

12 A

Voltage

~ 120 V, 60 Hz

No load speed

10000 - 22500 rpm

Quick height adjustment

70 mm (2.76“)

Fine height adjustment

8 mm (0.31“)

Router diameter, max.

63 mm

Drive shaft connection of

the spindle

M 22x1

Weight

4.5 kg (9.9 lbs)

Protection class

/ II

Symbols

V Volts
A Amperes
Hz Hertz
~

Alternating current

n

0

No load speed

Class II Construction

rpm Revolutions or reciprocation per minute
Ø Diameter

Functional description

The pictures for the functional description

are on a fold-out page at the beginning of

the instruction manual. When reading of the

manual you can fold out this page for having

always an overview of the machine.
1.1 Speed

controller

1.2 Locking

button

1.3 On/Off

switch

1.4 Scale
1.5 Spindle

stop

1.6

Pivoted turret stop

1.7 Collet

nut

Use for intended purpose

The routers are designed for routing wood,

plastics and similar materials. Aluminium and

plasterboard can also be processed with cor-

responding cutters such as are listed in the

Festool catalogues.

The user is liable for damages

and injuries due to incorrect usage.

Electrical connection

The network voltage must conform to the

voltage indicated on the rating plate. A 16

A safety fuse (for 120 V) or a corresponding

protective circuit-breaker is required.
See the following fi gure for connection and

disconnection of the power cable.

Always switch the machine off

before connecting or disconnecting the power

cable!

2

Extension cable

If an extension cable is required, it must have

a suffi cient cross-section so as to prevent an

excessive drop in voltage or overheating. An

excessive drop in voltage reduces the output

and can lead to failure of the motor. The table

below shows you the correct cable diameter as

a function of the cable length for the router OF

1400 EQ. Use only U.L. and CSA listed exten-

sion cables. Never use two extension cables

together. Instead, use one long one.

Total Extension Cord

Lenght (feed)

25

50

100 150

Cord size (AWG)

16

14

12

10

Note: The lower the AWG number, the stron-

ger the cable.

Switching the ma-

chine on and off

Keep the machine steady dur-

ing switching and during use by holding the

handles (3.1, 3.4) with both hands.
Switch (3.3) serves as an On/Off switch. It

may be latched with the locking knob on the

side (3.2) for continuous operation. Pressing

the switch again releases the lock.

Advertising