550f, Operation, Viewing and adjusting the setpoint – Frymaster CT16 User Manual

Page 6

Advertising
background image

3

• Phase:

Single

• Service: 30 Amp

Setup:

Setup of the toaster consists of unpacking the unit, placing it on a sturdy table or countertop adjacent to
a properly grounded AC outlet of appropriate voltage, removing the cardboard packing inserts, installing
the bun feeder in the slot on top of the cover, and plugging it in. NOTE: The cover must be closed to
install the bun feeder, and the bun feeder must be removed to open the cover.

The unit is shipped with a programmed setpoint of 550

°F (288°C), upper crown compression knob set

to 4, lower crown compression knob set to 5, upper heel compression knob set to D, and lower
compression knob set to E. The operator may change these settings to attain desired toasting.

4. Operation

1. Press the ON/OFF

button. The word LOW will appear in the green LED display window. The

unit will take about 10 minutes to reach operating temperature, at which time the display will change
to REDY, indicating the toaster is ready for use.

2. Load buns into the appropriate slots (Heel or Crown) one at a time, with the cut faces toward the

rear of the unit. The unit will toast the buns and transfer them to the holding tray.

3. Adjust the setpoint and bun compression as necessary to achieve desired toasting.

5. Viewing and Adjusting The Setpoint

To view the platen temperature: Press the

button once. The temperature in degrees Fahrenheit

will appear in the green LED display window. To view the current setpoint, press the

button twice.

The setpoint in degrees Fahrenheit will be displayed in the green LED display window.

LOWER

SETPOINT

BUTTON

ON/OFF

BUTTON

LED

DISPLAY

RAISE

SETPOINT

BUTTON

DISPLAY

TEMPERATURE

BUTTON

550F

To change the display from Fahrenheit to Celsius: Unplug the unit, then press and hold the
button as the unit is plugged back in.

To change the setpoint:

1. Turn the unit OFF (press the

button). Enter the setpoint programming mode by pressing the

,

,

,

buttons in that order. The current setpoint will appear in the LED display. To increase

the setpoint, press the

button; to decrease it, press the

button.

2. When the desired setpoint is displayed, press the

button once. Press the ON/OFF

button. If

the platen is within 20

°F (11°C) of the setpoint, the display will show REDY. Otherwise, the display

will show LOW or HIGH until the platen is within 20

°F (11°C) of the setpoint, at which time the

display will change to REDY.