Operator troubleshooting – Frymaster CT16 User Manual

Page 8

Advertising
background image

5

5.

Rotate the tray stabilizer latch upward to unlatch it.

Tray

Stabilizer

Latch

6.

Slip the old belt off the rollers and slip the new belt on. When the replacement belt has been
properly positioned between the raised edges of its rollers, rotate the tray stabilizer latch to the
latched position.

7.

Press down on the top roller to unlock it and allow it to extend.

8.

Close the cover. Return the bun compression knobs to their previous settings.

8. Operator Troubleshooting

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

PRO1

PRO1

PRO1

PRO1 in LED display.

A.

Indicates failure of main platen probe or
associated circuitry.

A.

Call FASC.

PRO2

PRO2

PRO2

PRO2 in LED display.

B.

Indicates failure of holding tray resistor.

B.

Call FASC.

A.

Cover not properly installed.

A.

Make sure cover is correctly positioned so
that the cover interlock switch is
depressed.

B.

Toaster not plugged in.

B.

Plug toaster in.

C.

Store circuit breaker tripped.

C.

Reset circuit breaker.

Bun conveyors do not start

when ON/OFF button is

pressed.

D.

Failed cover interlock switch, failed high
limit, failed motor, or failed controller.

D.

Call FASC.

Toasting is consistently too

dark or too light.

A.

Improper setpoint programmed and/or
incorrect compression knob setting.

A.

If toasting is too dark, lower the setpoint
and/or compression setting until desired
toasting is achieved.

If toasting is too light, increase setpoint
and/or compression setting until desired
toasting is achieved.