Before turning the switch to the

“Auto” position, make sure that the tool

connected to the tool plug socket is switched off.

When you turn the switch to “Auto” the dust

extractor will not come on until you turn on the

tool connected to the tool plug socket. When you

turn off the tool, the dust extractor will

automatically switch off. When you turn the tool

back on, the dust extractor will automatically

start.

Suction force regulator (1.2)

The suction force regulator lets you set the

suction force that works best for the material to

be vacuumed up.

Connecting an electric tool

Observe the maximum connected load on the

tool plug socket (see “Technical Data”). The tool’s

rated power consumption must not exceed this!

Plug the tool power cord to the tool plug socket

(1.3).

Make sure the tool is switched off

when you plug or unplug it!

Intended use

This dust extractor is designed for the aspiration

and evacuation of non-toxic, non-hazardous

dusts, dirt, sand, shavings etc., and for

vacuuming water.

This dust extractor is designed in accordance with

IEC 60 335-1 and IEC 60 335-2-69 for a higher

loading in industrial use.

The user is solely responsible for

any damage or accident caused by using this

machine for other than its intended purpose.

Getting started

Electrical connection

The operating voltage shown on the specification

plate must be the same as the mains power

voltage (wall socket).

Make sure that the dust extractor

is switched off when you plug in the power cord.

On/off switch (1.1)

In position O the dust extractor is switched off

and the tool plug socket (1.3) is dead.

Two modes of operation are possible:
a) Switch at “MAN” (manual control):

The tool plug socket is live.

Before turning the switch to the

“MAN” position, make sure that the tool

connected to the tool plug socket is switched off.

When you turn the switch to “MAN” the extractor

motor will start immediately and will stay on as

long as the switch is at this position.

You can also use this mode of operation without

a tool connected to the tool plug socket.
b) Switch at “Auto” (automatic tool-

triggered operation):

The tool plug socket is live.

No adapter should be used with this appliance.

If the appliance must be reconnected for use on

a different type of electric circuit, the

Technical data

CT MINI

Power consumption

400 - 1,200 W

Max. connected load to tool plug socket

1,200 W

Total connected load max. (vacuum cleaner and

plug socket)

2,400 W

Max. airflow volume, turbine

168 m

3

/h (6,04 cu.ft./h)

Max. vacuum, turbine

20,000 Pa

Filter surface

5,000 cm

2

(775 sq. in.)

Suction hose, diameter x length

22 mm x 3,5 m (0.87 in. x 11.48 ft.)

Tank capacity

10 l (2.6 gal.)

Dimensions L x W x H

440 x 340 x 420 mm (17.3 x 13.4 x 16.5 in.)

Weight

9.5 kg (21 lbs)

Power cord length

7.5 m (24.6 ft.)

Protection type

IP X4

reconnection must be made by qualified service

personnel.

SAVE THESE INSTRUCTIONS