Use

During the following procedures,

take care not to raise unnecessary dust.

Changing the filter bag

- Open locking clips (1.4), remove top section

(1.5).

- Change filter bag (2.1) – see instructions printed

on filter bag.

- Replace top section, close locking clips.

Note: A replacement filter bag can be stored in

the storage compartment (5.4).

Changing the filter

Do not operate this dust extractor

without a filter, as doing so may damage the

motor.

- Open locking clips (1.4), remove top section

(1.5).

- Fold over handle (3.1) and remove holder (3.2).

- Remove used filter (3.3) and replace with a new

one.

- Replace holder and fold over handle until it

latches into place.

- Replace top section, close locking clips.

Emptying the dirt trap

The dirt trap (2.2) can be emptied after removing

the top section.

Stand

Extending the stand (4.5) keeps the dust

extractor from rolling.

To do this, lift the front end of the dust extractor

slightly and push the stand downwards until it

latches into place.

Press the button (4.4) to release the stand.

Application

The extractor hose (4.2) is connected to the

extractor opening by the angle tube (4.1). During

operation, the extractor hose goes through the

hose opening (4.3).

A Systainer can be attached to the top of the

storage area (5.6) via the four locking clips (5.5).

Note: If this is done, the power cord must run

through opening (5.3).

Vacuuming dry materials

Do not do any dry vacuuming or dust extraction

of dry substances without a filter bag in the tank!

This protects the motor, and lets you dispose of

the evacuated material easily.

The filter becomes damp after evacuating liquids.

A damp filter will suffer accelerated wear if it is

used for dry materials. Accordingly, allow the

filter to dry or replace it with a dry one before

dry operation.

Vacuuming liquids

If foam or liquid escapes, stop

immediately and empty the tank.

The filter bag must be removed before evacuating

liquids. We recommend using a special wet filter

for wet vacuuming.

When the maximum fill level is reached, a level

stop (3.4) will automatically interrupt extraction.