Ar-15 voltage regulator / power conditioner, Lift (linear filtering technology), Extreme voltage shutdown indicator – Furman Sound AC LINE VOLTAGE REGULATOR AR-15 User Manual

Page 4: Protection ok indicator, Fuses and circuit breakers

Advertising
background image

AR-15 VOLTAGE REGULATOR / POWER CONDITIONER

accidental connections to 208 or 240 VAC, by

shutting off the incoming power until the over

voltage condition is corrected.

LiFT (Linear Filtering Technology)

Unfortunately, traditional AC filter - condition-

ers have been designed for unrealistic labora-

tory conditions. Prior technologies, whether

multiple pole filter or conventional series

mode, could actually harm audio and video

performance more than they help, due to the

resonant peaking of their antiquated, non-lin-

ear designs. Under certain conditions, these

designs can actually add more than 10 dB of

noise to the incoming AC line! Furman’s SMP+

with LiFT takes another approach, ensuring

optimal performance through linear filtering

and no leakage to ground. With this exclusive

filtration technology, all connected equipment

will be free of noise and contamination and will

operate at optimum performance levels.

Extreme Voltage Shutdown Indicator

This LED is normally off. It monitors a hazard

common in the entertainment industry: wiring

faults – for example, accidental connection

to 220VAC where 120VAC is expected, or an

open neutral from a 208 or 240VAC feed. The

Series II SMP+ circuit senses voltages that

are so high that operation would be impossible

and shuts the power down before damage

can occur. Upon initially applying power to

these units, the Extreme Voltage indicator

LED will light if the input voltage is above the

extreme voltage cutoff, and power will not be

applied to the unit’s outlets. If the unit has been

operating with an acceptable input voltage

and subsequently that voltage exceeds 145-

150V, it will shut off power to the outlet and the

Extreme Voltage LED will light.

NOTE: If the mains power is above the high

cutoff voltage and has caused the unit to

remove power from its outlets, it cannot restore

power without the operator manually turning

the unit off, then on again. Avoid turning the

unit back on, without first checking the source

of the problem, and perhaps changing the AC
source.

Protection OK Indicator

Although the Furman SMP+ circuit assures

virtually protection from transient voltage

spikes and surges, nature has a way of

occasionally creating electrical forces that are

beyond the capabilities of any TVSS device to

absorb without some degree of damage. In

the rare instance that this occurs, the green

“Protection OK” LED indicator located on your

front panel will dim. If this happens some level

of protection from voltage surges will remain,

but the Furman’s clamping voltage rating will

be compromised. The unit must be returned

to Furman Sound, or an authorized Furman

Service center for repair.

FUSES AND CIRCUIT BREAKERS

There is one fuse and one circuit breaker in the

AR-Series. In the event that the unit appears to

be completely dead (neither the Power switch

nor any LED’s light up), unplug the power cord

and the load and check the breaker. If the cir-

cuit breaker is tripped, a white button will pop

up. Push it back in to reset it. The purposes of

these circuit protection devices are:
1. A fast-blow 15 amp circuit breaker is acces-

sible at the rear panel without removing the

unit from the rack. This breaker will trip if the

unit’s 15 amp capacity is exceeded at any

time.

2. A fast-blow 1/4 amp fuse is located inside

3

Advertising