SPECIFICATIONS

Spike Protection Modes:

Line to neutral, zero ground leakage

Spike Clamping Voltage:

188 Vpk @ 3,000 amps, 133 VAC RMS

(tested to UL-1449 6,000 Vpk @ 3,000 amps)

Response time:

1 nanosecond

Maximum surge current:

6,500 amps

Voltmeter Accuracy:

±5V

“In Regulation” Ranges:

AR-15 II: Provides regulation ±5V in 120V mode from
97 to 141V

Noise attenuation:

10 dB @ 10 kHz
40 dB @ 100 kHz
100 dB @ 10 MHz

Linear attenuation curve from 0.05 - 100 ohms line impedance

Shutdown Range:

Above 145 - 150VAC typically

Dimensions:

19 “ W x 11.63” D x 1.75” H

(48.26 x 29.54 x 4.45 cm)

Weight:

14.5 lbs. (6.58 kg)

Current Rating:

The AR-15 II is capable of 15 amps for input voltages
of 124V (104V in 100V mode) or higher; derate at 113

mA per volt to a minimum of 12:3A

Three Year Limited Warranty:

The AR-15 is protected by a limited three-year warranty covering defects
in materials and workmanship.

Furman Sound, Inc. • 1997 South McDowell Blvd. • Petaluma, CA 94954-6919 USA

Phone: 707-763-1010 • Fax: 707-763-1310 • Web: www.FurmanSound.com • E-mail: [email protected]

Made in China

12/17/04-C

SERVICE

Before returning any equipment for repair,

please be sure that it is adequately packed

and cushioned against damage in shipment,

and that it is insured. We suggest that you

save the original packaging and use it to

ship the product for servicing. Also, please

enclose a note giving your name, address,

phone number and a description of the

problem.
NOTE: All equipment being returned for

repair must have a Return Authorization

(RA) Number. To get an RA Number, please

call the Furman Service Department, (707)

763-1010, ext. 120 or 121, between 8 a.m.

and 5 p.m. U.S. Pacific Time, or fax to (707)

763-1310. Please display your RA Number

prominently on the front of all packages.

Advertising