Inspecting burners, Operating heater, Continued – FMI VFN30R User Manual

Page 16: Pilot flame pattern

Advertising
background image

16

105072

UNVENTED NATURAL GAS LOG HEATER

FIREPLACE MANUFACTURERS INC.

Thermocouple

Pilot Burner

Figure 25 - Correct Pilot Flame Pattern

Figure 26 - Incorrect Pilot Flame Pattern

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 25 shows a correct pilot flame pat-
tern. Figure 26 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.

If pilot flame pattern is incorrect, as shown
in Figure 26

• turn heater off (see To Turn Off Gas to

Appliance, page 15)

• see Troubleshooting, pages 18 through 20

Thermocouple

Pilot Burner

OPERATING
HEATER

Continued

Figure 23 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment
Knob for Remote Operation

O

F

F

PIL

OT

O

N

LO

IH

ON
OFF
REMOTE

Selector Switch in
Remote Position

Control Knob in
On Position

Flame Adjustment Knob

Figure 24 - Thermostat Hand-Held Remote Control Unit Selections
(GHRCTA Series Only)

Increases Room
Temperature in
AUTO Mode

Decreases Room
Temperature in
AUTO Mode

Turns Burners
On or Off and
Allows You to
Choose the Auto
Setting

Shows
Temperature
Setting

The Log Heater
will Automatically
Cycle between
Pilot and the Heat
Setting that has
been Selected

IMPORTANT:

This remote control

has been specially engineered to take
an air temperature sample every 5.5
minutes in the auto mode. It will not
respond immediately to the tempera-
ture setting being turned up or down.

IMPORTANT:

The hand-held remote

control unit must be near the heater.
Do not keep the hand-held remote
control unit too close to the heater.
The thermostat on the hand-held re-
mote control unit will heat up too
quickly and turn the heater off.

3.

To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.

IMPORTANT:

To turn the pilot off,

manually turn the control knob on
the heater to the OFF position.