FUJITSU FTP604 User Manual
Page 33

12-02-2003
Page 5-33 of
- 5-33 -
51
5 Specifications
5.1
Electrical Data
Voltage:
6-8,5VDC
Current:
Maximum head current:Numbers of active dots * Vhead
150+/-15%
Maximum motor current:
1000mA
Power up sequence:
max. 10 msec. 10 – 90% Voltage applied
Power down sequence:
max. 10 msec. 90 – 10% Voltage applied
5.2
Mechanical Data
Dimensions: Length, width, height: 77 mm* 50 mm * max. 15 mm
Including connectors.
Vibration:
100G XYZ
Shock:
100G XYZ
5.3
Environmental Data
Operation:
Temperature:
-20°C- +85°C
Humidity :
10%-99% RH, without condensing
Storage:
Temperature:
-40°C - +85°C
Humidity:
0%-99% RH, without condensing
Transport:
Temperature:
-40°C - +85°C
Humidity:
0%-99% RH, without condensing
5.4
EMC & ESC
The printer controller is tested according to:
Emission: E-Field:
EN50081-1-1
Conducted:
EN50081-1-2
Immunity: E-field:
EN50082-1-1
Conducted transients:
EN50082-1-2
Over voltage:
EN50082-1-3
Medical equipment:
IEC601-1-2