Port assignment of the fc pass-thru blades, 3 port assignment of the fc pass-thru blades – FUJITSU PRIMERGY BX600 S2 User Manual

Page 117

Advertising
background image

PRIMERGY BX600 S2 Basic Unit

117

FC Pass-Thru Blade

FC Port Assignment

11.3

Port Assignment of the FC Pass-Thru
Blades

FC pass-thru blades can be installed in slots NET3 and NET4 on the rear of the
base unit. The FC pass-thru blade in slot 1 provides a bypass connection
between channel A of the installed fibre channel daughter cards and the corre-
sponding optical transceivers. The FC pass-thru blade in slot 2 provides a
connection to channel B of the installed fibre channel daughter cards.

Figure 69: Slot numbering for the Fibre Channel pass-thru blades

V

CAUTION

●

FC pass-thru blades must always be installed in slot NET3 first. This
ensures that port A of the FC daughter cards is connected if
redundant fibre channel connections are not used.

●

If Gigabit Ethernet daughter cards are installed in the server blades,
LAN switch blades (see

page 81

) or Ethernet pass-thru blades (see

page 99

) must be installed in slots NET3 and NET4.

Asynchronous balanced mode of Ethernet blades and fibre channel
blades in slots NET3 and NET4 is not permitted.

NET4

NET3

Advertising