4 refrigerant cycle – Friedrich CP05N10A User Manual

Page 9

Advertising
background image

—8—

2.3.6 POWER CORD

1. Disconnect the unit from source of power.
2. Remove the front grille. (Refer to Section 2.1.1)
3. Remove the cabinet. (Refer to Section 2.1.2)
4. Remove a screw that secures control panel to

base pan. (Refer to Section 2.1.3)

5. Pulls the control board toward you.
6. Disconnect the 2 receptacles and remove the

grounding screw.

7. Remove a screw securing the clip with cord to the

control panel.

8. Pull the power cord.
9. Re-install by referring to procedures above.

2.4 REFRIGERANT CYCLE

2.4.1 CONDENSER

1. Remove the cabinet. (Refer to Section 2.1.2)
2. Discharge the refrigerant by using a refrigerant

recovery system.

3. Remove the air guide. (Refer to Section 2.2.1)
4. Remove 2 screws which fasten the condenser.
5. After discharging the refrigerant completely,

unbraze the interconnecting tube at the
condenser connections.

6. Remove the condenser.
7. Re-install by referring to the procedures above.

Figure 18

Figure19

Advertising