Plumbing, Clearance and access information – Follett MU155N Series User Manual

Page 5

Advertising
background image

Plumbing

Dispenser

3/4" PVC slip joint for hopper drain
3/4" PVC pipe nipple for beverage drain pan
3/8 ID red line tubing for water in

Note:

Drains should be hard-piped and insulated. Maintain at least 6mm per
304mm run slope on drain line run

Icemaker

Refer to Icemaker Installation Manual packed with icemaker for installation instructions

Clearance and access information

• 1296mm above counter
• 305mm on side opposite tower, below counter
• Counter front or rear panel must be removable for service access to both sides of dispenser and

icemaker(s), if any

• Below counter access to drain clean-out required on utility side of dispenser
• See Icemaker Installation Manual packed with icemaker(s) for clearance requirements for automatic

load dispensers

4

Side view

Front view

553mm

305mm

305mm

696mm

712mm

1264mm

794mm

305mm

min

480mm

min

153mm min

480mm

min

432mm

661mm

water

connection

hopper drain

beverage
pan drain

Automatic load units with 1 icemaker

Automatic load units with 2 icemakers