Electrical connection – Foster live quality 7331 230 User Manual

Page 15

Advertising
background image

29

ELECTRICAL CONNECTION

The installation of this appliance and the connection to the electrical network should be

entrusted only to an electrician perfectly to the fact of the normative regulations and which

respects them scrupulously.

Protection against the parts under tension must be ensured after the building-in.

The data of connection necessary are on the stickers place on the hob casing near the

connection box.

The connection to the main must be made using an earthed plug or via an omnipolar

circuit breaking device with a contact opening of at least 3 mm.

The electrical circuit must be separated from the network by adapted devices, for example:

circuit breakers, fuses or contactors.

Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.

Connect always the earth wire.

Respect the connection diagram.

The connection box is located underneath at the back of the hob casing. To open the cover use a

medium screwdriver. Place it in the slits and open the cover.

* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990

Connection of the hob
Setting up the configurations:

For the various kinds of connection, use the brass bridges which are in the box next the terminal

Monophase 230V~1P+N

Put the 1

st

bridge between terminal 1 and 2, the 2

nd

between 3 and 4.

Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 3, the Phase L to one of

the terminals 1 or 2.

Biphase 400V~2P+N

Put a bridge between terminal 3 and 4.

Attach the earth to the terminate “earth”, the neutral N to terminal 4 or 3, the Phase L1 to the

terminals 1 and the Phase L2 to the terminal 2.


Caution! Be careful that the cables are correctly engaged and tightened.

Mains

Connection

Cable diameter

Cable

Protection calibre

230V~ 50/60Hz

1 Phase + N

3 x 2,5 mm²

H 05 VV - F

H 05 RR - F

25 A *

400V~ 50/60Hz

2 Phases + N

4 x 1.5 mm²

H 05 VV - F

H 05 RR - F

16 A *

We cannot be held responsible for any incident resulting from incorrect connection or

which could arise from the use of an appliance which has not been earthed or has been

equipped with a faulty earth connection.

Advertising