OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS cont.

WARNING:

Always remove the power

plug from the wall outlet before

assembling or removing accessories.

INSERTING THE TELESCOPIC

TUBE INTO THE MAIN UNIT

• Insert the telescopic tube into the hole

next to the dust cup handle. Make

sure that the slot in the handle fits

correctly into the opening. (See

illustration.)

• To remove the telescopic tube, press

the telescopic tube release button and

pull the tube up.

EXTENDING THE TELESCOPIC
TUBE

Push the plastic button and pull out the
smaller tube. See illustration below

.

ATTACHING THE FLOOR BRUSH

TO THE MAIN UNIT

• Insert the floor brush into its location,

in the direction of the arrow.

• To remove the floor brush from the

main unit, press on the floor brush

release button and pull the floor brush

out.

ATTACHING THE HOSE TO THE

MAIN UNIT

• Hold the end of the hose (see

illustration below).

• Insert the hose into the hose

connector (see arrow in illustration).

Warning

:

After each Use -

Always remove the Filter

Assembly and the Dust Cup

Cover with the Debris Screen,

then vigorously “TapClean” HEPA

Filter and clean Debris Screen

until no more dust can be

removed.

4. Hold the HEPA filter

by the edges and

vigorously “TapClean”

the HEPA Filter dirty

side down on a hard,

flat surface until no

more dust is observed

falling out from

between the pleats of

the filter.

5. Rinse the non-woven pre-filter and

let d\air dry completely for 24 hours.

6. Insert the non-woven pre-filter.

7. Reinstall the HEPA filter in the

vacuum.

8. To Separate the Debris Screen from

the dust cup, hold the dust cup in one

hand and turn the dust cup cover

counter clockwise and pull apart. To

clean the Debris Screen, we

recommend that

you rinse it under

lukewarm running

water to remove

the dirt that

accumulates on it, but

always allow 24 hours to air dry

before inserting back into the vacuum.

Warning:

Always unplug the

unit from electrical outlet before

opening the Dust Cup (container).

2. To empty the dust

cup container,

press on the trap

door release button

that is on the back

side of the dust cup

container.

Dust

Cup

Release
Button 2

Dust

Cup

Release
Button 1

HEPA
Filter

Non-Woven
Pre-Filter

3. The HEPA filter is located underneath

the dust cup container. (See

illustration.) Remove the non-woven

pre-filter. Remove the HEPA filter,

hold the edges and pull it out slowly.

Emptying the Dust Cup Container
and Cleaning / Changing the Non-
Woven Pre-Filter, HEPA Filter &
Debris Screen

Important:

Do NOT use the vacuum

without the HEPA filter in place.

1. To remove the dust cup container,

first press on the dust cup release

button (1) that is located on the dust

cup handle and at the same time

press on the dust cup release button

(2) that is on the side of the upper

housing. See illustration below. Then

pull the dust cup container out.

IMPORTANT, Please Note : The

“TapClean” HEPA Filter will stop most of

the tiniest dust particles from re-entering

the air you breathe. In fact it stops 99.97%

of all particles as small as 0.3 microns -

many times smaller than a human hair!!!

Because of this incredible filtration

performance, the HEPA Filter will quickly

accumulate, inside the white filter folds,

many fine dust particles that are difficult to

see but which will eventually block or

reduce your suction power - if not cleaned

properly.