Technical data, Symbols, Scope of delivery – Festool MFK 700 User Manual

Page 8: Intended use, Electrical connection, Extension cable

Advertising
background image

8

Technical data

Power consumption

720 W

Rotational speed (no load)

10000 - 26000 rpm

Tool holder

8 mm (0.31")

optional:

6 mm (0.24")

1/4"(6.35

mm)

Max. routing tool diameter

26 mm (1")

Weight

1.9 kg (4.2 lbs)

Safety

/II

Symbols

V Volts
A Amperes
Hz Hertz
~

Alternating current

n

0

No load speed

Class II Construction

rpm Revolutions or reciprocation per

minute

Ø Diameter

Warning of general danger
Read the Operating Instructions/

Notes!

f

Advice or tip

Scope of delivery

The pictures for the scope of delivery are on a

fold-out page at the beginning of the instruc-

tion manual. When reading of the manual you

can fold out this page for having always an

overview of the machine.
[1-1] MFK 700 with large surface router ta-

ble

[1-2] Side stop with guide rods and fi ne ad-

juster

[1-3] Extraction hood for large surface router

table with extractor connector

[1-4] Router table for edge veneer with feeler

roller and extraction hood (only in SET

scope of delivery)

Intended use

The MFK 700 EQ is designed for routing wood,

plastic and similar materials.

The user shall be responsible

and liable for damages and accidents

resulting from misuse or abuse of this

tool.

Electrical connection

The network voltage must conform to the

voltage indicated on the rating plate. A 16

A safety fuse (for 120 V) or a corresponding

protective circuit-breaker is required.
See the following fi gure [2] for connection and

disconnection of the power cable.

Always switch the machine

off before connecting or disconnecting

the power cable!

2

Extension cable

If an extension cable is required, it must have

a suffi cient cross-section so as to prevent an

excessive drop in voltage or overheating. An

excessive drop in voltage reduces the output

and can lead to failure of the motor. The table

below shows you the correct cable diameter as

a function of the cable length for the MFK 700.

Use only U.L. and CSA listed extension cables.

Never use two extension cables together. In-

stead, use one long one.

Total Extension Cord

Lenght (feed)

25

50

100 150

Cord size (AWG)

18

16

16

14

Note:

The lower the AWG number, the stronger

f

the cable.