Fireplace installation, Venting installation, Continued mantel clearances – FMI PENINSULA WOODBURNING FIREPLACE (V)PN36-A User Manual

Page 6: Optional outside air kit

Advertising
background image

www.fmiproducts.com

115607-01D

6

FirePlace insTallaTion

Continued

MANTEL CLEARANCES

Woodwork such as wood trims, mantels or

any other combustible material projecting from

the front face must not be placed within 9" of

fireplace opening.
Combustible materials above and projecting

more than 1

1

/

2

" from the fireplace front face

(see Figure 11) must not be placed less than 12"

from effective opening of the fireplace (NFPA

STD 211, Sec. 7-3.3.3).
Mantels or any other combustible material

may also come up to the side edge of the

black metal face of the fireplace only if the

projection from the front face falls within limits

shown in Figure 12.

Figure 12 - Mantel Clearances to Metal

Face

VenTing insTallaTion

OPTIONAL OUTSIDE AIR KIT

The installation of an outside air kit should

be performed during the rough framing of

the fireplace due to the nature of it’s location.

Outside combustion air is accessed through

and exterior wall or a vented crawl space.

CAUTION: Air inlet ducts

must not terminate in attic

space.

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

For further details on installation of outside

air kit, please refer to instructions included

with air kit.

8" Max.

“K” Factor

.84

1

1

/

2

" Typ.

1

1

/

2

" Typ.

Noncombustible

Hearth

Extension

“Z” Type Ember

Protector

Noncombustible

Hearth Extension

Ember Protector

Figure 10 - Raised Hearth Extension

Front

Face

Fireplace Front View

Fireplace Side View

3" Nom.

9" Min.

12" Min.

33°

6" Nom.

1

1

/

2

" Max.

Drywall

2" X 4" Stud

Combustible

Materials

Figure 11 - Mantel Clearances to

Combustible Materials

Seal Gaps with

Noncombustible

Mortar or Adhesive

Top View of Fireplace

Drywall

4"

(Approx.) 33°

Nom.

6" Nom.

4

3

/

8

"

Min.

Combustible

Material Must

Not Overlap

Black Metal

Front Face

2

3

/

4

" Max.

Figure 9 - Hearth Extensions

65" Min.

64" Min.

20" Min.

16"

Min.

Advertising