2 maintenance requirements – FUJITSU MHV2080AS User Manual

Page 17

Advertising
background image

1.1 Maintenance

C141-F073

1-3

1.1.2 Maintenance

requirements

(1) Preventive maintenance

The disk drive needs no preventive maintenance, not even the air filter needs to be
changed.

Device damage

The DE is completely sealed. Do not open the DE in the field.

(2) Service life

In situations where management and handling are correct, the life of the disk drive
is five years or 30,000 hours of operation, whichever occurs first. Refer to
Section 1.7 and 3.2 in Product Manual.

(3) Exchangeable parts in field

The PCA and the DE cannot be replaced separately in the field. Replace the
whole disk drive.

(4) Service system and repair

Fujitsu Limited has a disk drive service system and repair facility. When making
a request for repair or parts replacement, you should provide related information
usually including:

a) Model name of disk drive, part number (P/N), disk drive revision number,

manufacture serial number (S/N), and date of manufacture of the disk drive

b) Circumstances when the fault occurred

− Date of trouble occurred

− System configuration

− Environmental conditions (including temperature, humidity, and voltage)

c) Fault history of the drive

d) Details of the fault

− Description of the fault

− Issued command and specified parameters

− Status (Status/Error register)

− Interval of the fault

− Other information for fault diagnosis