2 receiver pinouts, Figure 16 7, Table 5 7 – Foxconn Interfacility Link 7870 User Manual

Page 29: Table 5 7870r receiver pinout

Advertising
background image

3.3 7870 Interfacility Link Pinouts

7870 Interfacility Link Installation and User’s Guide

page 21

Foxcom proprietary information

3.3.2

Receiver Pinouts

Note

If a 2380 Relay Adapter is installed RF and Optical Levels are measured

together; the alarm indicates a problem in either the RF or optical levels.

Figure 16 7870R Receiver pinout

Caution

When monitoring the voltage outputs use only a high resistance DVM.

Standalone

9 Pin

Connector

[J14]

7180M Chassis

Backplane

Connector

2380 Relay

Adapter

Connector

Name

Description

1

+14V Power 350 mA

2

Spare

Not Used

3

J11-P9

J12-P25

J13-P25

J4-P25

GND

Chassis Ground

4

J13-P1 to J13-P8

J4-P1 to J4-P8

RSSI

RF signal strength
indicator:
range 0.2 - 10 V

5

J13-P9 to J13-P16 J4-P9 to J4-P16 PDI

Indicates input optical
power: 1 V/ 1 m optical
power

6

Spare

Not used

7

J12-P1 to J12-P8

J2: P1-P2

P3-P4, P5-P6

P7-P8, P9-P10

P11-P12

P13-P14

P15-P16

RFA

RF Alarm: Open collector
interface.

1

Sinks current

when RF level is low, up
to 30 mA.

8

J12-P9 to J12-P16 See note below

OPTA

Optical Alarm: Open
Collector Interface

1.

.

Sinks current at low
optical, up to 30 mA.

9

Spare

Not used

Table 5 7870R Receiver Pinout
1.

If the 2380 Relay Adapter is installed, the alarms are dry contact. See Appendix 3 The

2380 Relay Adapter on page 33.

Advertising