Operating instructions – FRIGIDAIRE 2020266A0107 User Manual
Page 4
 
4
Operating Instructions
2009 Electrolux Home Products, Inc.
All rights reserved.
Operating Instructions
(continued)
4. You can also use the FAN button to change the fan speed to HIGH or LOW. The indicator light will show the 
 setting you have selected. A higher fan speed will result in quicker moisture removal.
5. The FILTER RESET light will illuminate after 250 hours of operation. At this time refer to the care and cleaning 
 section to remove and clean the filter. Once the filter has been cleaned, to extinguish the light simply press the 
 FILTER button.
3. After a few days when the Relative Humidity has declined, press the HUMIDITY or buttons to choose a value 
 between 35% to 85%, so the room is kept at a comfortable concentration. Pressing the or buttons will 
 change the humidity selection in 5% increments. After you have set the desired humidity, the readout will display 
 the actual room humidity. If at any time you want to return to the CONTINUOUS Mode, pressing the HUMIDITY
 button will lower the Relative Humidity through the 5% increments until the display reads CO.