Hardware installation

4.2

Setting up the floorstand model

I

If you are not installing a PRIMERGY TX200 S6 floorstand model, skip
this section and continue reading at

section "Installing/removing the rack

model" on page 49

.

V

CAUTION!

Follow the safety instructions in

chapter "Important information" on

page 31

.

Ê

Transport the server to the place where you want to set it up.

Ê

Unpack the server (see

section "Unpacking the server" on page 46

).

Ê

Set up the server.

Note that for safety reasons (danger of tipping) the anti-tilt bracket must be
mounted on the back of the server (see section

"Mounting the anti-tilt

bracket" on page 48

).

V

CAUTION!

–

The device must be protected from direct sunlight.

–

The essential minimum clearance for servicing must be
maintained (see

"Maintenance area for the floorstand model" on

page 27

).

–

Access to the rear of the server must be assured so that other
devices (e.g. memory subsystems) can be connected.

–

A clearance of at least 200 mm must be maintained in front of and
behind the system to ensure proper ventilation.

–

The mains plug must be accessible easily and safely.

Ê

Wire the server. Read the information in

section "Connecting devices to the

server" on page 59

and

section "Notes on connecting/disconnecting cables"

on page 63

.

Ê

Connect the system to the mains (see

section "Connecting the server to the

mains" on page 60

).