Dimensions (Base unit specific)
Environmental
Rack mounting kit
Rack mounting kit as option
Rack (W x D x H)
482.6 mm (Bezel) / 444.8 mm (Body) x 765.0 mm x
176.0 mm
Mounting Depth Rack
728 mm
Height Unit Rack
4 U
19" rackmount
Yes
Mounting cable depth
rack
100 mm (1000 mm rack recommended)
Noise emission
Measured according to ISO 7779 and declared
according to ISO9296
Sound pressure
(LpAm)
< 50 dB(A) (standby)
< 50 dB(A) (operation)
Sound power (LWAd;
1B = 10dB)
< 6.5 B (standby)
< 6.6 B (operation)
Noise notes /
description
at ambient temperature < 23°C
Operating ambient
temperature
10 - 35°C
Operating relative
humidity
10 - 85 % (non condensing)
Exhaust air volume
Ambient temp. m
3
/h m
3
/min
<25°C
49
0.82
30°C
87
1.45
35°C
126
2.1