Natural gas vent-free fireplace system, Installation, Check gas type – FMI FMH26TN User Manual

Page 8: Installation items, Locating fireplace

Advertising
background image

8

107105

NATURAL GAS VENT-FREE FIREPLACE SYSTEM

WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

You can recess firebox into the wall. You
can also position fireplace in the optional
cabinet or corner mantels.

IMPORTANT:

Only use optional cabinet or corner mantels
specified in this manual. Purchase the op-
tional mantel from your dealer (see Acces-
sories,
page 26).

CAUTION: This fireplace cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to fireplace. Installing
fireplace next to vinyl or cloth
wall coverings or operating fire-
place where impurities (such as,
but not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.

WARNING: Never install the

fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the fireplace

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

IMPORTANT:

Vent-free fireplaces add mois-

ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Air for Combustion
and Ventilation,
pages 5 through 7.

INSTALLATION

WARNING: Maintain the mini-

mum clearances shown in Fig-
ures 7 and 8. If you can, provide
greater clearances from floor,
ceiling, and joining wall.

Note:

Your vent-free fireplace is designed

to be used in zero clearance installations.
Wall or framing material can be placed
directly against any exterior surface on the
rear, sides, or top of your fireplace, except
where stand-off spacers are integrally at-
tached. If standoff spacers are attached to
your fireplace, these spacers can be placed
directly against wall or framing materials.

Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9).

CHECK GAS TYPE

Use only natural gas. If your gas supply is
not natural gas, do not install fireplace. Call
dealer where you bought fireplace for proper
type fireplace.

INSTALLATION ITEMS

Before installing fireplace, make sure you
have the items listed below.

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• ground joint union
• sediment trap
• tee joint
• pipe wrench

* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional CSA design-certified
equipment shutoff valve from your dealer.
See Accessories, page 26.

Note:

If desired, purchase a four-sided brass

trim kit for built-in installations. See Acces-
sories,
page 26.

CAUTION: If you install the

fireplace in a home garage
• fireplace pilot and burner must

be at least 18 inches above floor.

• locate fireplace where moving

vehicle will not hit it.

6"

Minimum
From
Sides Of
Fireplace

Left
Side

CEILING

36"
Minimum

FLOOR

Right
Side

Figure 7 - Mounting Clearances As Viewed
From Front of Fireplace Shown Built In
The Wall

Top Of
Mantel Can
Be Flush
With Wall

Left
Side

CEILING

Right
Side

36"
Minimum

Figure 8 - Mounting Clearances As Viewed
From Front of Fireplace Shown with
Optional Mantel

LOCATING FIREPLACE

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

Note:

When installing fireplace directly on

carpeting, tile or other combustible material,
other than wood flooring, the fireplace shall
be installed on a metal or wood panel extend-
ing the full width and depth of the fireplace

0" Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material

0" Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material

Advertising