Furuno FAR2XX7 User Manual

Page 5

Advertising
background image

ARPA Information:

Configure the FAR2xx7

The ARPA target output must be setup through the LAN for all the FAR2xx7.
Hold “HL OFF” and pres the “MENU” key 5 times.
The “Initialize” menu appears.
First, select “ARP Preset” (6). Select “True” for “TTM Output” (2)
Select “Back” to return to the “Initialize” menu and select “Other” (8).
Set “INS” (5) to “LAN”. Repeat this process for each processor on the network.

Configure MaxSea

Open the MaxSea Connection Wizard and select “Manual Port Configuration”


Select “UDP Connection”:


Select the Network Adapter corresponding to the computer IP address then type “10028”
for the UDP port.

Note: If you acquire an ARPA target on the FAR2xx7, you should see $TTM sentences
flow in the window.

Click on “Next”. When MaxSea is done analyzing the port, the following window will
appear. Select “UDP 10028” in the list and make sure that “ARPA” is checked.

Advertising