Error display – Furuno CI-80 User Manual

Page 38

Advertising
background image

34

Error display

“OK” appears for normal memory IC test. For fault NG (No

Good) and asterisk (*) appear next to ROM/RAM number.

Table 3 Error number display and meaning

Error

number

Reason

Circuit board

to check

000

Input voltage

JCPA, JIFA

001

Overheated transducer element

JLGA, JCPA, JIFA*

002

Abnormal Tx B voltage

STXA, UPW, JCPA

003

Tx voltage of beam 1

JCPA, STXA

004

Tx voltage of beam 2

JCPA, STXA

005

Tx voltage of beam 3

JCPA, STXA

006

Tx current of beam 1

JCPA, STXA

007

Tx current of beam 2

JCPA, STXA

008

Tx current of beam 3

JCPA, STXA

100

External position data

JCPA, JIFA

101

External speed data

JCPA, JIFA

102

External time data

JCPA, JIFA

103

External depth data

JCPA, JIFA

104

Heading data

JCPA, JIFA

105

Heading error angle

JCPA, JIFA

106

Water temperature data

JCPA, JIFA

200

External KP input interval

JCPA, JIFA, abnormal external KP

interval

201

Depth sensor input

JLGA, JCPA, JIFA,

faulty temperature sensor

202

Inclinometer roll signal

JCPA, JIFA, no inclinometer data

203

Inclinometer pitch signal

JCPA, JIFA, no inclinometer data

* Abnormally high Tx voltage, abnormally low transducer

impedance, too high Tx duty, faulty temperature sensor (faulty

element), high water temperature, and other factors may also

cause this error display.