3.7 Confirming Magnetron Heater Voltage

Magnetron heater voltage is adjusted at the factory. Confirm that magnetron heater
voltage is within the prescribed rating as follows:

1. Turn on the radar and select the 0.125 mile range.

2. Press [RADAR MENU] [0] [0] [0] [2] [0] to

open the INITIAL SETTING2 menu.

3. Press [5] to select the 5. SCANNER

STOPPED field and the TX option.

4. Turn off the antenna switch in the display

unit.

5. Connect a multimeter, set to the 10 VDC

range, between #12(+) of P801 and the
chassis.

6. The multimeter should read 9.2-9.4 V. If not,

adjust VR1.

7. “Transmit” on the 48 mile range.

8. The multimeter should read 7.3-8.3V.

9. Press [RADAR MENU] [0] [0] [0] [2] [0] [5]

to select the 5. SCANNER STOPPED field and the ROTATE option.

10.Turn on the ANT MOTOR SW on the scanner unit.