Safety label, Caution, Attention – FMI PELLET STOVE GF55 User Manual

Page 4: Inst alla tion, Greenfi re pellet stove and insert owner's manual 4

Advertising
background image

Greenfi re Pellet Stove and Insert Owner's Manual

4

INST

ALLA

TION

SAFETY LABEL

This is a copy of the label that accom-
panies each GF55 & GFI55. We have
printed a copy of the contents here for
your reference.

On the GF55 the safety label is located
on the underside of the hopper lid.

On the GFI55 the safety label is located
on the hopper cover behind the top
faceplate.

T

o

Start Stove:

Press

the ON / OFF button. If the au

ger

needs to be pr

imed, press the Manual

Auger

Feed button until fuel starts to drop into the Burn Pot.

T

o

Operate

Stove:

MANUAL

MOD

E:

When

a

fire

has

been

established

the

s

tove

set

tings

are

adjustable.

/

H

IGH/LO

WM

O

D

E:

(Requires

a

the

rmostat)

W

hen

the

the

rmostat

c

al

ls

for

heat

the

stove

s

ettings

are

adjustable.

When

the

thermostat

contacts

open,

the

HEA

T

L

EVEL

and

Fans

will

d

rop

down

to

the

L

OW

set

ting

until

the

thermostat

c

ontacts

c

lo

se

again.

/

A

UT

O/OFF

MODE:

(Requires

a

thermostat)

W

hen

the

the

rmostat

c

ontacts

c

lose,

the

unit

will

light

automatically

.

O

nc

e

up

to

temperat

ure

the

stove

s

ettings

a

re

adjustable.

When

the

the

rmostat

c

on

tacts

open,

the

s

tove

will

drop

down

to

the

L

OW

set

tings

for

30

minutes.

If

within

the

3

0

m

in

the

thermostat

contac

ts

close,

the

HEA

T

L

EVEL

will

return

to

previous

MANU

AL

setting

o

r

if

the

thermostat

c

ontacts

remain

open the s

tove begin it

s sh

utdown routine.

T

o

T

u

rn

Of

f Stove: MA

NUAL

an

d HI

/ LOW mode: Press

the ON / O

FF button

AUT

O / OFF mo

de:

T

u

rn the thermostat down or of

f.

The

u

ni

t

c

a

nb

ei

nst

al

led

on

a

hard,

stable non-

comb

ustible

surf

ace.

L'unit

é

peut

être

inst

allée

sur

u

n

dur

,

la

surface non-combustible stable.r

.

Certified

for us

e in Canad

a &

USA

Cert

ifié

pour

inst

allation

au

Canada

et aux

Eta

ts-Unis.

Listed Room

Heater

, Pe

lletized Fuel

T

y

pe

(Appareil

de chauf

fage à granules certifié)

Suitable For

Mobile Hom

e Installation

(Accepté pour

l'instal

lation dans une m

aison mobile, test)

T

e

sted to (

T

e

stée selon):

U

L

14

8

2

-1

9

9

8

/

U

LC

S

6

27-00

/

A

S

T

M

1

5

0

9-

9

5/

U

LC

S

6

2

8-

M9

3

Thi

s pellet appliance has been tested and

liste

d f

or use

in manufactured homes in ac

cord

ance with

Oregon

Administration Rules 814-23-900 through 814-23-909.

Instal

l and us

e only in accordance with the Manufacture’s

installation and oper

ating instructi

ons. Contact lo

cal building or fire offic

ials about restrictions and in

sta

llation inspectio

n in

you

r area. Do not connect this u

nit to a chimney flue serv

ing

another ap

pliance. See lo

cal

building c

odes and

manufacturers

instructi

ons

for precautions

required

for passing a chimney thr

ough a combustib

le wall or ceiling. Electrical

rating: 120 volts, 60 hz, 4.3 Amps. Route cord aw

ay

from the heater.

Cet appareil a été testé et ce

rti

fié pour utilis

ation

dans les maisons mo

biles en

accord avec les "Règles

Administ

rat

ives de l'Oregon 814-23-900

à 814-23-909". Installez et utilis

ez

cet ap

pareil seu

lement

selon les

instructions d'installation et d'opération du fabricant. Contactez

les autorités locales de v

otre quartier concernant les

restrictions et les

inspections d'installation. Consultez les codes de bâtiment lo

caux et les instructions

du

fabricant

pour

les

préc

autions à pren

dre lorsque une cheminée doit

être instal

lée au travers un mur ou un plafond

combust

ible. CLASSEMENT

ÉL

ECTRIQUE : 120 V

olts

, 60 Hz, 4.1

Amps. Placez le câble électrique loin de l

a

chaleur

.

For

Use With Only Pe

lletized Wood f

uels. Operate onl

y with viewing door and ash removal door

cl

osed. Onl

y re

place

glass w

ith cera

mic glass. Componen

ts required for in

sta

llation: a 3 inch (75 mm) or 4i

nch

(100 mm) list

ed PL vent,

complete with components. Insert an

d Hearth mount install

ations; a l

ist

ed single wall chimney

liner may be used. Inspect

and clean Exha

ust

Ve

nting system f

req

uently.

Utilisation

avec les combustibles sous forme de bou

lets un

iquement.

Utiliser seulement lorsqu

e les portes avants et la

porte du r

écept

acle

de c

endre sont fermées. Si une ou des vitres devaient être remplac

ées,

utilisez seulement

du

verre c

éramique. Les composantes requises pour l'installation son

t un év

ent PL

certifié de 3in/75mm or 4in/100mm

avec ses compo

santes.

Les installatio

ns

inser

tion et de

mont de foyer

; un paquebot

de ch

emin

ée de mur

de s

eul

énumér

é peut être ut

ilisé.

Input Rating (Les

données évaluant):

12

,000 to 45,000 BTU/Hr (3.5 to 13.2 kWh

)

334

DATE OF MANUFA

CTURE

/

DATE DE FABRI

CATION:

GF55-081

J F

M A

M J

J A S O

N D

2008 2009

2010

CAUTION:

Hot

while

operating. Do not

touch, severe burns

may

resul

t. Keep chil

dren, clot

hing,

furniture, gas

oline or other

flammabl

e vapors away

.

A

TTENTION:

Très chaud

quand allumé. Ne touche

z pas,

les brûlures sévères p

euvent r

ésulter.

Tenez

loin des enf

ants, des

vêtements,

des

meubles,de l’es

sence ou d’autres f

luides

produis

ant des vapeurs infla

mmables.

DO NOT REMOVE THIS LABEL /

NE RETIREZ P

A

S CETTE ÉTIQUETTE

See installation and oper

ating

instruct

ions accompanying

appliance.

/

Consult

ez le manuel av

ec les instruct

ions d’inst

allation

et d’opération

.

A

S

idewall

to Unit

(Du mur de côté à l'appareil

)

8

” (203 mm)

B

T

op of u

nit to an uns

hielded 8” (20

3 mm) man

tle

(Le sommet de

l'unité

à un m

anteau de c

heminée

non blindé) 8” (203 mm)

C

Unit

to top

facing (protruding ¾” [19 mm])

(De l'unité au s

ommet

du

pa

rement)

8” (20

3 mm)

D

Unit to side

fac

ing (

protruding ¾” [19 mm])

(De l'

unité

au côté du parement)

8” (203 mm)

E

F

rom door opening of

unit to edge of flo

or protection

(De

la po

rte ou

vran

t au de

vant de protec

tion de plancher)

6

(152

m

m)

F

F

rom side of un

it

to edge of floor protect

ion

(De l'

ouver

ture

de

porte pour

prendre

parti de p

rotection de plancher)

6” (152 mm)

Combus

tible floors must be protected by a

non-c

ombustible material.

- See Owners

Manual.

Le plancher combustible doit êtr

e protégé par

un matériel incombustible.

- Consultez le manual.

INSTALLED AS A F

IREPLACE INSE

RT STO

VE MODEL (GFI55) / A INSTALLE

COMME UN MODÈLE

SUR PIED DE POELE.

Min

imum clearanc

es to combustib

le materials./ Les dégagement

s minimums aux matériels

combustibles:

A

S

idewall to U

nit

(Du mur de côté à l'appareil)

6

” (152 mm)

B

B

ackw

all t

o Unit (Du mur de der

rière à l'appareil) 3”

(76 mm)

C

Corner to Unit (Du co

in à l'appareil)

2” (51 mm)

D

W

all to v

ent (Le mur pour donner vent)

3” (76 mm)

E

F

rom door opening of unit to edge of flo

or protection

(De la po

rte ou

vran

t au de

vant de protec

tio

n de plan

cher)

6

(152

mm

)

N

OTE:

A

combustibl

e

floor

m

us

tb

e

protected

b

yan

o

n

-

c

om

busti

ble

m

ater

ia

l

-W

idth

27"

(686m

m)

by

depth

34"

(864mm).

(U

n

p

lancher

combusti

ble

d

oi

te

tr

e

prot

ege

par

u

n

mater

iel

incom

bust

ible.

La

largeur

27"

(686

m

m)

par

la

pr

ofondeur

34"

(86

4

m

m).)

Minimum Alcove

Width (

La largeur minimum de l'alcove)

36” (914 mm)

Minimum Alcove Height (La

hauteur minimum de l'alcove)

48” (1219 mm)

Maxi

mum Alco

ve

Depth (La profondeur maximum de l'alcove)

3

0” (762 mm)

INS

TAL

LED

AS A FREESTAN

DING

STOV

E MO

DEL (GF55) / A IN

STAL

LE COMME UN

MODÈLE FS, QU’IL SOIT ENCASTRÈ

, SUR PIED OU DANS UNE MAISON MOBILE.

Minimum

cle

aranc

es to c

ombustible materials./ Les dégagement

s minimums aux matér

iels

combustibles:

Ser

ial N

o. / No. De Se

rié:

Greenfire GF55 (Stove) GFI55 (

Insert)

Mod

el /

Modèle:

15956

B

A

D

C

Adjacent

wall

F

E

Floor Prot

ection

A

B

C

E

Backw

all

Sidewall

D

Pou

r démarrer le poêle:

Appuyer

sur le bout

on "ON/OFF". Si

le

Auger

nécessite d'être am

orc

é, appuyer sur l

e bouton manuel d'ali

men

tati

on du

Aug

er jusqu'à ce que l

es

granules

se déversent dans

le pot de co

mbu

stion.

Pou

r

faire

fonctionner

le

poêle

:

MOD

E

MANU

EL

:

Lorsque

le

feu

est

bien

établi,

les

rég

lages

peuvent

être

ajustés.

/

M

OD

E

"HI

GH/LOW"

:

(Nécessite

un

thermostat)

Lorsque

le

the

rmostat

requière

d

e

la

cha

leur

,

les

réglages

peuvent

être

ajustés.

Lorsque

les

contacts

d

u

thermostat

ouvrent,

le

réglage

du

niveau

de

chaleur

et

les

v

entilateur

s

s

'ajusteront

au

réglage

"

bas

"

jusqu'à

c

e

que

les

c

ontacts

d

u

thermostat

s

e

ref

erment.

/

MODE

"AUT

O/OFF"

:

(Nécessite

un

thermostat)

Lorsque

les

c

ontacts

d

u

thermostat

ferment,

le

poêle

s'allumera

automatique

men

t.

Lorsque

la

températ

ure

adéquate

est

a

ttein

te,

les

réglages

peuvent

être

ajustés.

Lorsque

les

c

ontac

ts

du

the

rmostat

ouvrent,

le

poêle

s'ajustera

aux

réglages

"LO

W"

pendant

30

minutes.

Si

les

c

ontac

ts

du

thermostat

sont

fermés

pendant

ces

3

0

minutes

, le ré

glag

e de niv

eau de chaleur retournera en r

églages "MANUEL"

ou si les

contac

ts du therm

ostat rest

ent ouver

ts, le poêle entam

era le pr

ocessus d'arrêt

.

Pour é

teindre le poêle :

MODE MANUEL

ET

" H

IGH/LOW " :

Appuyer sur le bou

ton "ON/OFF".

MODE "AUT

O / OFF" : Régler le thermostat à la b

aisse ou ét

eignez le.

Man

ufactur

ed in Canad

a for

/

Fabriqué dans

le Ca

nada pour

:

FPI Fi

replace

Products I

nternational

Ltd.