19

S

TEP

12:

Strip

3

/

16

" off the ends of the low voltage wire and

twist tightly. These wire ends will be attached to
the control board at the 18VAC terminals located
on the POWER IN terminal block (see Illustration
L
). Wire sheathing should not come in contact
with terminals, however, it should not be stripped
so far that wires can come in contact with one
another (see Illustration K).

Insert one transformer wire
into an 18VAC terminal.
Insert the other transformer
wire into the remaining
18VAC

terminal (see

illustration L). Transformer
wires can be connected to the
18VAC terminals regardless
of color.

Tighten set screws against
exposed end of wires (see
Illustration K
). A dab of
household petroleum jelly on
each wire end will help
prevent corrosion.

The ACCESSORY terminal
block provides the connection
point for safety loops, wands,
push buttons, intercoms, card
readers, etc. See page 27 for
more information about
connecting accessories.

S

TEP

13:

Plug the transformer into the electrical outlet. Check to see if
the green LED on the control board is on. If it is not, see the
Troubleshooting Guide on page 30.

NOTE: Use of a surge protector is strongly recommended.

SURGE PROTECTOR

Transformer

HINT: Keep a few mothballs in the control
box to discourage insects from entering it
and damaging the control board.

I

NSTALLATION

OF

THE

GTO T

RANSFORMER

C

ONT

.

Illustration L

Correct

Wrong

Wrong

Wire

Terminal
Block

Terminal
Block

Terminal
Block

Wire

Wire

Illustration K

FIRST OPERATOR

POWER IN

18VAC SOLAR

~ ~

+

RED

BLK

ORG

BLU

GRN

CLS EDG

OPN EDG

RE

RED

BLACK

RED

BLACK

Power Cable

from First Operator

Low Voltage Wire

from AC Transformer

SECOND OPER