Installation instructions, Technical specification, Packing checklist – Stovax AR0368 User Manual

Page 8

Advertising
background image

8

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

Covering Models:

MANHATTAN - 8619 - P8619

Packing Checklist

Qty Description
1

Stove

1

Flue Blanking plate

1

Flue In fill plate

1

Coal set*

1

Flame Baffle*

1

Front Coal*

1

Fixing kit containing

1

Instruction Manual

2

Wood screws

2

Rawlplugs

1

Box spanner

*Packed in appliance

Model

CAT.

Gas

Gas

Type

Working
Pressure

NOX

Class

Aeration

Injector Gas Rate

m3⁄h

Input kW (Gross) Country

High

Low

Steel Manhattan 8619

I

2H

Naural Gas G20

20 mbar

5

ø11 mm

375

0.629

6.6

Gross

6.6

Gross

GB,IE

Steel Manhattan P8619

I

3+

LPG Propane G31
LPG Butane G30

37 mbar
29 mbar

5

ø15.5 x 2

170

0.237

0.18

6.30

Gross

3.25

Gross

GB,IE

Efficiency Class II

Flue Outlet Size 127 mm (5”) ø

Gas Inlet Connection Size 8 mm ø

Minimum flue specification T300/N2/O/D/1
Maximum flue temperature 260°C

A

A

A

AA

B

D

E

C

A

B

C

D

E

ins

mm

ins

mm

ins

mm

ins

mm

ins

mm

27

7

/

8

709

27

683 16

3

/

4

42

17

7

/

8

453

5

3

/

4

145

Advertising