Step Three

Arrange the hose at the cylinder end so that none will kink and they
are hanging free. Put a piece of tape on the right hose at the cylinder
end to identify it. You will need to know this when it’s time to
connect the hose to the cylinder. See Fig.14.
Step Four

Get into the boat close to the E-H unit. Bring the Remote Handheld,
fluid, and some rags. Remove the screw that locks the E-H unit in
place so that you can move the unit around. Remove the tank plug by
unscrewing counterclockwise and remove. Note the tank has two
fluid level lines on it. The upper line is the full line and the lower line
is the low fluid line.

Step Five ( Purge Air)

Take the open end of the continuous loop of black hose,
and insert it into the tank as shown in Fig. 15. Be sure
that the other end of black hose is secure on the left
barbed fitting on the E-H unit. Also make sure that
the clear kinked hose is also secure on the right barbed
fitting. (Use of tie wraps may be necessary)
Turn the pilot on by momentarily pressing and releasing
the deckmount switch. When the Stby LED quits
blinking, press the top button on the remote (Auto/Stby)
the Auto Led will be lit. Holding the tube in the tank
press the

Left Straight Arrow. Refer to fig. 15. The

fluid level will go down. Let the button up and place
system in

STBY when the fluid is low and refill the

tank. (

Do not press the Straight Right Arrow Button,

you will blow the clear tube off the right side and

create a hydraulic fluid mess)
You may need to fill the tank several times. Keep the

hose submerged in the tank fluid and keep pumping until bubbles stop
appearing in the tank.

Turn the system to standby by momentarily pressing the top

button (AUTO/STBY) on the handheld. Turn the unit off by
pushing in the deckmount button and hold until the lights are

out (about to the count of 5). Remove the hose from the tank,

keeping your thumb over hose to prevent air from entering or

losing fluid. Insert the tank plug, fitting it securely into the top

of tank. Tilt the fitting end of the E-H unit back and remove

the kinked shipping hose from the E-H. Now push the rubber

hose onto the right fitting pushing firmly until fully engaged

over barbs. Install the Two (2) Hose clamps over the hose and

barbed fittings at the manifold and tighten. See Figure 15-a.

You will need the clear shipping tube again in the next step

so don’t throw it away yet.