30

Automated Setup Codes

Calibrate Compass

47

Hold Down Select Load Button, press and release Deckmount

Button to start Calibration Process

Load Factory Compass 49

Hold Down Select Load Button, press and release Deckmount

Button to reload factory Compass Calibration

Load Factory Pilot

59

Hold down Select Load Button, press and release Deckmount

Button to Reload Factory Pilot Settings

Throttle Speed

24

1 lowest speed, 10 highest speed

5

Throttle Delay

25

1 least delay, 10 most delay

5

Throttle Codes

Tachometer Codes

Setup Action

Code # Range of Settings or Responses

Default

Stby Safety Monitor

349

2 settings on, off, defaults to on every power up

on

Tach on/off

34

2 settings on, off

on

Show RPM

36

1000’s blink on up Arrow

Hold Down Select Load Button:

100’s blink on down Arrow

Hydraulic Codes

Reverse Hoses

259

2 settings normal up arrow lit, reverse down arrow lit

normal

Special Function Setup Codes

Degrees per Step

6

10 choices/1,2,3,4,5,10,15,30,45,or 90 Degrees

15

Circle Time

7

10 choices/ 1,2,3,4,5,10,,15,30,45,or 90 Minutes

5

Zig-Zag Amplitude

8

10 choices 5 to 50 degrees by 5’s

30

Zig-Zag Period

9

20 choices 1 to 20 minutes by 1’s

3

MOB overshoot

28

1 most overshoot command, 40 most undershoot command

20

Cloverleaf Length

29

500 ft to 1000 ft by 50 ft increments

1000

Search Spacing

249

50 ft to 1000 ft by 50 ft increments

50