Servicing continued – Garland CG-72 User Manual

Page 11

Advertising
background image

G_GC_SM_CHAINGRIDDLE_GCGTRAINING06 (03/19/13)

Page 11

7. The bayonet connector is spring loaded. Turn the

connector so that it makes good contact with its seat on
the plate, and adjust the spring so that at least 1” (25mm)
of spring is available to push home. This is, it is loaded 1”
(25mm) from the bayonet adapter.

8. Once this adjustment is made, remove the thermocouple

from its cavity, pry the old heat sink material from the
cavity and apply fresh heat sink compound (Garland
Commercial Ranges part #77024).

9. Re-assemble the unit.

Incandescent Lamps

These lamps, similar in construction if not in shape to
ordinary incandescent light bulbs, sometimes fail because
of metallurgical breakdown of the light fi lament material.
The green status light (PL1) should illuminate when the main
switch SW1 is closed.

If PL1 doesn’t illuminate when SW1 is closed, replace it.

Failure of the amber lights (PL3, PL4, etc.) monitoring the
zones cycle with the thermostat is not easy to detect.
When on, an amber zone light is working. If it does not
appear to light as part of the ‘burner on’ cycle, check. If
the thermostat cycles the burner to be on, the PL amber
light should illuminate.

Pilot Ignition Control (Control Module)

The Johnson G770 pilot ignition unit will lock out if the pilot
fl ame is not sensed before the end of the ignition trial period
and has to be reset.

To reset the ignition control, turn off the thermostat for a
minimum of 30 seconds.

Bayonet

adapter

Adjust to
about 4.5"
before
installing

About 1"
before compression

Griddle plate

Probe heat

shield assembly

Figure 3 – Replacing a thermocouple

SERVICING continued

Advertising