Dimensions and specifications – Garland CG-72 User Manual

Page 4

Advertising
background image

G_GC_SM_CHAINGRIDDLE_GCGTRAINING06 (03/19/13)

Page 4

DIMENSIONS AND SPECIFICATIONS

FRONT VIEW [Model CG-48R]

Optional Stand

Finished Floor

Grease Drawer(s)
2' & 3' Units - One
4', 5' & 6' Units - Two

Available in 24, 36, 48, 60 & 72 Widths

610, 914, 1219, 1524 & 1829

2.5

84

3.25

83

24

610

38.75

984

6

152

1.5

38

5

127

Grease Trough

Electric

Cord/Connection

Gas Connection Centered

On Unit Width [Left to Right]

20

508

5.5

140

PLAN VIEW [Model CG-48R]

Dimensions - All Models

DIMENSIONS:

Inches

mm

5.75

146

0.625

16

10

254

35

889

4.75

121

15

381

10

254

27

686

6

152

15.75

400

Cooking Surface

Electric Cord/Connection

Gas Connection

Rear

Gas Inlet

Counter

Counter

Leg

Removable

Grease

Drawer

Optional

Stand

Finished

Floor

SIDE VIEW

3" [76mm] Extended Bumper

to Prevent Flue Vent Blockage

INPUT CHART - Natural Or Propane Gas

Model

Number

BTU/
hour

kW

Gas

Inlet

Shipping

Weight

lb./kg.

CG-24R

60,000

17.60

3/4"

335/152

CG-36R

90,000

26.40

3/4"

485/220

CG-48R

120,000

35.00

3/4"

625/284

CG-60R

150,000

44.00

3/4"

765/348

CG-72R

180,000

52.70

1"

995/411

Combustible Wall Clearances

Sides: 6” (152mm)

Back: 6” (152mm)

IMPORTANT:

Unit must be
installed on legs for proper air
circulation.

Ventilation

Commercial cooking equipment
requires an adequate ventilation
system.

Refer to the National Fire
Protection Association’s standard
NFPA96.

Manifold Pressure Required
After Built-in Regulator

Natural:

3.5" W.C. (8.75mbar)

Propane:

10" W.C. (25mbar)

Minimum Supply Pressure Required:

Natural:

7" W.C. (17.4mbar)

Propane:

11" W.C. (27.4mbar)

NOTE

Gas Input Ratings shown are for
installations up to 2,000 feet (610mm)
above sea level.

BTU input ratings must be derated for
high altitude installations.

Electrical Requirements

Specifi cations:

120 V, Single Phase, 60Hz, 1 A

6’ (1829mm) power supply cord provided.

NOTE: No cord and plug on export units

Direct connection on junction box.

Export Voltages:

NOTE: Export voltages are available on
request.

220-240 V, 50 Hz, 0.4 A, Single Phase.

Advertising
This manual is related to the following products: