Setting Heater Control

(Refer to F

IG

. 11)

1.

Set the heater control knob (33) to a trial setpoint of
4 or 5.

2.

Start the pump and circulate fluid through the sys-
tem at very low pressure, about 10-12 oz/min
(0.30-0.35 liter/min).

3.

After 10 minutes, read the temperature on the ther-
mometer (2). If it does not match the desired tem-
perature, adjust the setpoint.

Adjusting for Spraying

1.

Adjust pump pressure and heater setpoint to the
lowest settings needed for good fluid atomization.

2.

Set all system back pressure valves (S - F

IG

. 1) to

maintain even fluid pressure at all gun stations.

F

IG

. 11: Setting Heater Control

33

05549-524

2

CAUTION

Operating the heater at its highest setting, over 180°F
(82°C), for long periods of time decreases the heater
life and can cause fluid to dry out; which can clog the
heater and result in a poor finish.