Technical Data

28

309524L

Technical Data

The heater can be used in the following environmental conditions: indoor use, 99% maximum relative humidity, pollu-
tion degree 2, installation category II, maximum ambient temperature 135° F (57° C).

*

Main supply fluctuation not to exceed 10%.

**

The heater has a surface temperature code of T2

(

482°F, 250°C), indicating a maximum external (surface) temperature rating

of 482°F (250°C) in accordance with EN 60079-0:2006 (IEC 60079-0:2004) and EN 60079-1:2007 (IEC 60079-1:2007). This
heater has a surface temperature code (identification code) of T2, indicating a maximum external (surface) temperature rating
of 250°C (482°F) in accordance with Article 500 - Hazardous Locations - of NFPA 70 National Electrical Code and/or Section
18 - Hazardous Locations - of Part 1 of the Canadian Electrical Code. Read and comply with the requirements of these and
similar codes as to proper location of the heater.

Maximum Working Pressure . . . . . . . . . . . . . . . . . . . . . . 7250 psi (50 MPa, 500 bar)

Voltage / Wattage / Current* . . . . . . . . . . . . . . . . . . . . . . . See Models, page 2

Fluid Passage Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 in.

2

(117,419 mm

2

)

Fluid Passage Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . 0.435 in. (11.1 mm)

Fluid Passage Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 in. (3383 mm)

Thermometer Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64–250°F (-18–121°C)

Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel

Temperature Operating Range . . . . . . . . . . . . . . . . . . . . . 84–219°F (-29–104°C)

Surface Temperature Code** . . . . . . . . . . . . . . . . . . . . . . T2 (482°F, 250°C)

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 lb. (17.6 Kg)

94.16

68.39

57.70

50.68

42.23

34.96

30.26

26.64

54.14

39.32

33.18

29.14

24.28

20.10

17.40

15.32

0

10

20

30

40

50

60

70

80

90

100

0

0.5

1

1.5

2

2.5

3

3.5

4000W
2300W

Maximum Temperature Rise vs. Flow Rate

4000 watt VISCON HP heater, Test Fluid: 10w Hydraulic Oil
2300 watt VISCON HP heater, Test Fluid: 10w Hydraulic Oil

NOTE: Line shows continuous operation of 1 heater.