K. ADDITIONAL FUNCTIONS
The following functions can be completed by the key operation described below.
The Accumulative cooking time and the number of door opening /closings can be observed.
The Type and level of the buzzer sound can be selected. The “display of remaining cooking time when
cooking is temporarily stopped due to door opening” can be selected. The “Accumulative cooking time
period” will inform the service technician of the life expectation of the magnetron or other parts.

4

5

6

7

1 ... Accumulative cooking time.
2 ... The number of door operations. (See “HINT” at Step 6)
3 ... Indication of remaining cooking time (when cooking

is interrupted by door opening).

4 ... To cancel remaining cooking time.
5 ... Tone of the buzzer on cooking completion. (Pip,

Pip, Pip)

6 ... Tone of the buzzer on cooking completion. (Peep)
7 ... The buzzer off.
8 ... The buzzer on.

Press START key.

All 4 digits will be flashing.

Press START key again.

The number “215”shows total cooking time in hours.

When number key other than 1 or 2 is pressed at step 4,
“0” appears in display window and the setting has been
completed.

Note:When number “2” is depressd at Step 4 above the
displayed figure shows the number of door operation

••100

e.g. “20” displayed=2000 door operations.

Press CLEAR / STOP key to clear the display for the

option 1 and 2. • The function is cleared and “0” will

appear in the display window.

1

START

START

STOP

CLEAR

LOW

MED.

HIGH

LOW

MED.

HIGH

LOW

MED.

HIGH

LOW

MED.

HIGH

LOW

MED.

HIGH

1

2

3

OPERATION

DISPLAY WINDOW

Press TIME key.

Press 8 three times.

Press CLEAR / STOP key.

KEY

STOP

CLEAR

TIME

8

LOW

MED. HIGH

LOW

MED. HIGH

LOW

MED. HIGH

Key operations at Step 1 thru Step 3 are common to all functions. Proceed with the key
operation at Step 4 for your desired functions.

• Select the function to press the number key

e.g. Number 1 key is pressed for

“Accumlative cooking time

period”