Garland EM-C180 User Manual

Page 7

Advertising
background image

- 7 -

Measure the resistance: Across two terminals with
an ohm-meter on highest scale.

COMPONENT

HIGH-VOLTAGE
CAPACITOR
Including internal
bleeder
resistor

HIGH-VOLTAGE
DIODE

Measure the resistance: Across two terminals with
an ohm-meter on highest scale.

CHECKOUT PROCEDURE

RESULT

Normal reading:

Momentarily indicates several ohms, and
gradually to 10 meg-ohms.

Abnormal reading:

Indicates continuity or 10 meg-ohms
from the beginning.

Normal reading:

Indicate about middle position in one
direction (forward) and infinite ohms in
the reverse direction, using ohm meter
with a 9V battery.

NOTE

- Some digital meter may show more
than 0 ohms or infinite ohms even in a
forward direction because the low mea-
suring voltage of the meter does not
allow the meter to pass through the high
voltage diode. Use an ohm meter with
a 9V battery.

Abnormal reading:

Indicates continuity or infinite ohms in
both directions.

Figure 7

Figure 8