4

3.0L GAS eNGINe SeRVICe ReCoMMeNdATIoNS

Maintenance Tasks

Level 1

Level 2

Level 3

Level 4

Recommended to

be done monthly/

10 hrs.

Task

Comp.

(Date-

Initials)

Required to be

done 3 months/

Break-in /30 hrs.

Task

Comp.

(Date-

Initials)

Required to

be done Semi-

Annually/50 hrs.

Task

Comp.

(Date-

Initials)

Required to be done

Annually/ 100 hrs.

Task

Comp.

(Date-

Initials)

1. Disable the unit from operating

per the first page warning.

•

•

•

•

2. Check the engine oil level. Adjust

as necessary.

•

•

•

•

3. Check the engine coolant level.

Adjust as necessary.

•

•

•

•

4. Check the engine coolant ther-

mal protection level. Correct as
necessary.

•

5. Check the natural gas delivery

system on gas engine driven
units. Tighten connections as
necessary.

•

•

•

6. Check the diesel fuel supply

level for diesel engine driven
units. Fill as necessary.

•

•

•

•

7. Drain water and sediment from

the diesel fuel tank on diesel
engine driven units.

•

•

•

8. Drain water from the fuel line

water separator on diesel
engine driven units if the unit is
equipped with one.

•

•

•

9. Check the air inlets and outlets

for debris. Clean as necessary.

•

•

•

•

10. Check the battery electrolyte

level if accessible. Adjust as
necessary.

•

•

•

•

11. Check the battery posts,

cables, and charger for loose
connections, corrosion, and
proper operation. Correct as
necessary.

•

•

•

•

12. Check the unit wiring for loose

connections, corrosion, and
damage. Correct as necessary.

•

13. Check the engine accessory

drive belts for wear, weather
cracking, and damage. Replace
as necessary.

•

Advertising