Installation continued – Garland G280-2 User Manual

Page 7

Advertising
background image

Part # 1382650 Rev 4 (12/07)

Page 7

INSTALLATION Continued

dealer. Installation must conform with the National Fuel Gas

Code ANSI Z223.1-1988 or latest edition, NFPA No. 54- Latest

Edition and National Electrical Code ANSI/NFPA 70-1990 or

latest edition and/or local code to assure safe and efficient

operation.

NOTE: The appliance and its individual shut-off valve (not

supplied by manufacturer) must be disconnected from

the gas supply piping system during any pressure testing

of that system at pressures in excess of ½ PSIG (3.45 KP2).

The appliance must be isolated from the gas supply piping

system by closing its individual manual shut-off (not

supplied by manufacturer) during any testing of the gas

supply piping system at test pressures equal to or less than

1/2 PSIG (3.45 KP2).

Installation for Ovens Equipped with Casters

A. The installation shall be made with a connector that

complies with the Standard for Connectors for Moveable

Gas Appliances, ANSI Z21.69/CSA 6.16, Addenda Z21.69B-

2006/CSA 6.16B-2006 (or latest edition), and a quick-

disconnect device that complies with the Standard for

Quick Disconnects for Use with Gas Fuel, ANSI Z21.41/

CSA 6.9, Addenda Z21.41A-2005/CSA 6.16A-2005 (or

latest edition).

B. The front casters of the unit are equipped with brakes

to limit the movement of the oven without depending

on the connector and any quick disconnect device or its

associated piping to limit the appliance movement.

C. Please be aware, required restraint is attached to the

bracket (which is located on the rear caster closes to the

gas connection), and if disconnection of the restraint is

necessary, be sure to reconnect the restraint after the

oven has been returned to its originally installed position.

Installation for Ovens Equipped with Legs

Raise front of the unit and block. Do not lay unit on its back.

Position leg insert into leg retainer opening and tap up until

it seats at collar flange. Repeat at rear of unit making sure all

four legs are adjusted to same height. Legs can be adjusted

to overcome an uneven floor.

Ventilation and Air Supply

Proper ventilation is highly important for good operation.

The ideal method of ventilating a range is the use of a

properly designed canopy which should extend six inches

(6”) beyond all sides of the appliance and six feet (6’) six

inches (6”) from the floor.

A strong exhaust fan will create a vacuum in the room for an

exhaust system vent to work properly, replacement air must

enter the room in which the vent is located.

All gas burners and pilots need sufficient air to operate and

large objects should not be placed in front of this oven which

would obstruct the air flow through the front.

Assembly of Battery

This section pertains to Master Series models only.

All heavy duty batteried equipment is aligned and fitted at

the factory, from left to right and must be installed in this

order. There is a diagram provided with every heavy duty

battery.

A. All such units should be placed in their respective battery

position. Detach valve panels to prevent damage,

remove them from the area where the battery is being

assembled.

B. Level each unit (to the oven rack) by adjusting the six inch

(6”) legs (refer back to Item 1 for limitations), or where

legs are not used, adjust level with shims. Readjust legs, if

required.

C. Connect units together by mating the unions at each

end of the manifold. (Adjoining units must have

matching unions, unless the union parts are of the

same specifications, a leak proof connection cannot be

assured.) Hand tighten unions at this point.

D. The units should be fastened at the rear by inserting

5/16” bolts through the holes provided at the rear of the

burner box sides. Be sure of proper unit alignment in the

battery before final tightening of these bolts or unions.

Improper tightening will cause the “fanning” or “bowing”

of batteries units.

The final tightening of the union should be accomplished

by using a suitable spanner wrench. If such a wrench is

not available, the Garland union collar has special ridges,

and a cold chisel can be driven against these ridges to

properly seat and seal the union.

E. The manifold of this unit or the manifold of which is

a part of must be equipped with a certified pressure

regulator suitable for battery application and adjustable

for an outlet pressure at the manifold as specified on the

rating place.

Advertising