Technical data / nozzle table – Gaggenau KG 291 User Manual

Page 19

Advertising
background image

17

Technical data (gas)

Burners: Normal

burner

Full burning

2.0 kW

Low burning

0.165 kW

Large burner
Full burning

4.0 kW

Low burning

0.165 kW

Wok burner
Full burning

5.0 kW

Low burning

0.3 kW

Total output

17.0 kW

Gas connection: R 1/2’’ union nut for R 1/2’’
bracket to DIN 1999, conical-cylindrical

Technical data (electrical)

Rated consumption

15 W

Voltage

AC 220-240 V

Frequency

50-60 Hz

Technical modifications reserved.

11. Technical Data / Nozzle Table

Countries

AT BE CH CZ

DE

BE CH CZ DK

AT CH DE

DE DK ES FI

ES FI FR GB

FR GB GR HU

GR HU IE IS

IE IS IT LU NL

IT LU NO PL

PL PT RU SE

PT RU

Gas family

Natural gas

Natural gas

LPG/Propane

LPG/Prop.

Gas type

H / E / L (G 20/25)

LL (G 25)

3 + (G30/31)

(G30/31)

Pressure

20/25 mbar

20 mbar

28-30/37 mbar

50 mbar

Nozzle, full burn, outer

1.55

1.70 B

1.00

0.87

Nozzle, low burn, outer

0.73

0.81

0.51

0.45

Nozzle, full burn, inner

0.58

0.63

0.37

0.33

Nozzle, low burn, inner

0.45

0.51

0.31

0.25

Air gap adjustm. outer [mm]

0

0

2

0

Air gap adjustm. inner [mm]

*

*

*

*

Total output

17 kW

17 kW

17 kW

17 kW

Total consumption

1.70 m

3

/h

1.87 m

3

/h

1240 g/h

1240 g/h

* open, fixed

Nozzle table wok burner

Advertising