Installation Instructions

C. INSTALLATION IN A

REMOTE LOCATION

(requires additional part)

1. Turn off the cold water supply.

2. Complying with plumbing codes, install a

fitting on the cold water pipe to adapt 1/4

OD tubing. A typical connection is shown
in illustration below. Make sure a water
supply valve is used.

3. If the RO unit is to be installed more than

6 feet from the valve, replace the yellow
tubing with a longer length of GE 1/4

tubing. A 33 foot length of 1/4

″ tubing is

available through GE Parts and Services
at 1.800.626.2002, part number
WS07X10018. DO NOT SUBSTITUTE
TUBING OF UNKNOWN QUALITY.

4. If the RO unit is to be installed more than 6

feet from the faucet, replace the blue tubing
with a longer length of GE 3/8

″ tubing. A 33

foot length is available through GE Parts
and Services at 1.800.626.2002, part number
WS07X10019. See Faucet Installation on
page 8 for more details. DO NOT
SUBSTITUTE TUBING OF UNKNOWN
QUALITY.

If you are using copper tubing, DO NOT
connect it directly onto the RO unit. Purchase a
connector and use a short length of the yellow
tubing provided to make final connection to RO.
Do not use copper tubing to attach to icemaker
or faucet.

7

Insert (not included)

Cold
water
pipe

1/4

″ (yellow) tubing

to inlet

Ferrule

Water supply valve

To RO