Cleaning, Trouble-shooting – Gardena 8000S SP User Manual

Page 6

Advertising
background image

15

GB

Flushing the pump :

Cleaning the suction
base and feed impeller :

The pump remains in constant operation because the float switch
is bypassed.

1. Push the float switch

5

onto the float switch lock

3

with the

cable downward.

2. Stand the pump on a firm surface

– or –
use a rope attached through the bore hole in the carrying
handle

2

to immerse the pump in a well or shaft.

3. Plug the power cable

1

into a mains socket.

The residual water height is only reached during manual opera-
tion since the float switch turns off the pump during automatic
operation before this water level is reached.

5. Cleaning

The pumps are virtually maintenance-free.

After having pumped chlorinated swimming pool water or other liq-
uids leaving residues, the pump should be rinsed with clear water.

Warning ! Electric shock !

A

Risk of injury due to electric shock.

V Disconnect the pump from the mains before clean-

ing the suction base and feed impeller.

1. Unscrew the 6 Phillips screws

8

(model 6500 SP: 4 Phillips

screws) and pull the suction base

6

off the pump.

2. Clean the suction base

6

and the feed impeller

9

.

3. Reinstall the suction base

6

and screw in the Phillips screws

8

.

For safety reasons a damaged feed impeller

9

can only be

exchanged by the GARDENA Service Centre.

6. Trouble-Shooting

Problem

Probable cause

Remedy

Pump is running,

Air cannot escape, since

v Open pressure line

but doesn’t deliver.

pressure line is closed.

(e.g. kinked pressure pipe).

Air locks in the suction base.

v Wait for max. 3 minutes

until the pump deaerates
automatically over the vent
valve. If necessary, switch
off and start it again.

Feed impeller clogged.

v Disconnect plug and clean

feed impeller (see 5. Clean-
ing).

When starting the pump,

v Submerge pump deeper.

water height falls below the
min. water level.

Manual operation :

9

6

8

1

2

3

5

Advertising
This manual is related to the following products: