8

WARNING: SAFETY PRECAUTIONS

Do not use the grill until a leak test has been
performed.

WARNING:

TEST FOR LEAKS

A complete gas tightness check must
be performed at the installation site.

To prevent fire or explosion hazard, DO NOT
use or permit sources of ignition in the area
while performing a leak test. Perform leak
test outdoors only. Never perform a leak test
with fire or flame. DO NOT SMOKE WHILE
PERFORMING THE LEAK TEST.

• Create a soapy solution of equal parts mild

dishwashing detergent and water.

• Check to be sure all controls are in the OFF

position.

• Turn on the fuel supply. For natural gas, turn

manual shut-off valve handle 1/4 turn to align
with gas flow. For LP, turn cylinder valve knob
counterclockwise one full rotation.

• Apply soap solution generously on all

connections and fittings. See illustrations.

• If growing bubbles appear on any connection

point, IMMEDIATELY turn off the gas supply.

To stop a gas leak:

• Turn on control knobs to release pressure.

Turn controls OFF.

• Wash off soapy solution and towel dry.

• Tighten the loose joint and perform a new

leak test.