2 installation – Gaggenau AW 200-790 User Manual

Page 15

Advertising
background image

14

6.2 Installation

The applicable regulations of the energy supply
companies and the regional construction
regulations must be observed when installing
the hood.

This hood has been approved for installations as
low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop.

The hood can be used in the exhaust or

circulating

air

mode. The exhaust air can be routed into a

separate exhaust air shaft or directly into the open
through the outside wall.

It is not allowed to pass the exhaust air into a flue
or exhaust air chimney that is in operation or into a
shaft that is linked to the heating basement. Consult
the chimney sweep responsible for your district
whenever you wish to pass the exhaust air into a
chimney that is not in operation.

During the course of planning, a chimney sweep
must be consulted if a room air-dependent hearth
is operated in the same room as the one in which a
hood is operated in the exhaust air mode. Adequate
incoming air must be ensured. The applicable
construction and safety regulations must be
observed.

Adequate incoming air must be ensured if a wood,
coal, gas or oil heater or an open hearth is operated
in the same room as the one in which the hood is
installed.

Safe operation is possible whenever the partial
vacuum in the place where the firing equipment
is installed does not exceed 4 Pa (0.04 mbar).
This can be achieved whenever the air needed for
combustion is able to enter through openings that
cannot be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or other technical
means.

Fig. 18

22”

10

1

/

4

3

15

/

16

16

7

/

8

5’3”

25

1

/

2

” -

5’1” hood height

min. 30”

7’4” - 9’9”

ceiling height

Advertising
This manual is related to the following products: