For circulating air mode use the installation set
included with the ventilation ducts LK 010-112/122
und LK 011-112/122. You also need an activated
charcoal filter (KF 001-010).
Proceed as follows:

– Slightly loosen the screws of the retaining bracket

for the chimney paneling. Hang the angle pieces
onto the screws and tighten the screws.

– Screw the circulating air switch module to the

angle pieces (4 screws).

– Shorten the flexible air pipe accordingly. Fix the

flexible air pipe with hose clamps (Fig. 24).

– Establish the electrical connection.

– Stainless steel chimney only (LK 010-112/122):

pull the protective film off the chimney’s trims.

Note: avoid damaging the sensitive metal surfaces.

– Fit the top chimney duct unit into the base. Make

sure that the fastening holes on the side are at the
top.

– Put both chimney duct units onto the hood.

– Pull the top chimney duct unit up into its final

position and secure it with 2 screws on the ceiling
holder (Fig. 25).

Note: avoid scratches when pulling the elements
apart by placing the assembly template, for
example, over the edge of the bottom chimney
paneling to protect it.

– Insert the activated charcoal filters.

– Insert the grease filters.

18

9000032538 en 06.05 EB

Fig. 24

Fig. 25