Plug-type circuit breaker amperage draw – Grizzly Model G0562 User Manual

Page 8

Advertising
background image

-6-

G0562 3 HP Dust Collector

The Model G0562 features a single phase 220V
3 HP motor.

Amperage Draw
220V .................................................... 18 Amps

Use the following guidelines when choosing a cir-
cuit breaker (circuit breakers rated any higher are
not adequate to protect the circuit):

Circuit Breaker
220V ..........................................20 Amp, 2 Pole

Figure 1. NEMA 6-20 plug and receptacle.

Figure 1a. 220 wiring diagram.

RED

WHITE

BLACK

YELLOW

MOTOR WIRES

GREEN (GROUND)

TO 220 VOLT
POWER SUPPLY

We recommend using a NEMA 6-20 plug (

Figure

1). You may also “hard-wire” the dust collector
directly to your panel, provided you place a dis-
connect near the machine. Check the electrical
codes in your area for specifics on wiring require-
ments. The motor is wired according to the dia-
gram in

Figure 1a.

Plug-Type

Circuit Breaker

Amperage Draw

SECTION 3: CIRCUIT REQUIREMENTS