SHIPPING

INFORMATION

MODEL

Weight

Lbs/Kg

HEEE-24CL

338/153

HEEE-36CL

391/177

HEEE-48CL

505/229

HEEE-60CL

620/281

Garland/U.S. Range products are not approved or authorized for home or residential
use, but are intended for commercial applications only. Garland / U.S. Range will not
provide service, warranty, maintenance, or support of any kind other than in com-
mercial applications.
Many local codes exist and it is the responsibility of the owner and installer to comply
with those codes
Gas Input ratings shown here are for installations up to 2000 ft. (610m)

Model #

Dimensions: In. (mm)

No. Of

Burners

Total BTU*

Gas Broiling Grid: In. (mm)

Width

Depth

Height

Natural Propane

Width

Depth

HEEE-24CL

24(610) 37-1/4(946) 17-13/16(453)

4

54,000

50,000

20-1/8 (511)

23-1/2(597)

HEEE-36CL

34(864) 37-1/4(946) 17-13/16(453)

6

70,000

72,000

30-1/8(765)

23-1/2(597)

HEEE-48CL

48(1219) 37-1/4(946) 17-13/16(453)

9

105,000

105,000

44-1/8(1121)

23-1/2(597)

HEEE-60CL

58(1473) 37-1/4(946) 17-13/16(453)

11

115,000

138,000

54-1/8(1375)

23-1/2(597)

* Manifold operating pressure as per table shown below

Gas Manifold 3/4" NPT on all models

38.75"

[978mm]

35.30"

[897mm]

.91"

[23mm]

4.61"

[112mm]

A
B
C

37.25"

[946mm]

8.47"

[215mm]

14.58"

[370mm]

17.84"

[453mm]

1.50"

[38mm]

28.71"

[729mm]

38.75"

[984mm]

ELECTRIC CORD CONNECTION

Width Measurements In (mm)

Model

A

B

C

HEEE-24CL

14.28 (363)

23.50 (597)

24.00 (610)

HEEE-36CL

24.38 (721)

33.50 (851)

34.00 (864)

HEEE-48CL

38.28 (972)

47.50 (1206) 48.00 (1219)

HEEE-60CL

48.28 (1226) 57.50 (1460) 58.00 (1473)

Models

Manifold Operating Pressure

Minimum Supply Pressure

Natural Gas

Propane

Natural Gas

Propane

"w.c.(Mbar)

"w.c.(Mbar)

"w.c.(Mbar)

"w.c.(Mbar)

All Models

4.0(10)

10.0(25)

5.0(12.5)

11(27.5)

Electrical : 120V, 60 Hz

Provided with NEMA 5-15P Power Cord Supply